A Quartz Sand Water Filter is a pressure filtration system designed to remove suspended solids, sediment, and particulate matter from industrial process water, groundwater, and surface water. It uses graded quartz sand as the primary filtration medium, supported by layers of gravel to maintain proper media distribution and water flow.
During operation, water passes through the quartz sand bed, where suspended particles are retained within the media layers. The filter is commonly installed as primary filtration equipment or as pretreatment before ultrafiltration (UF), reverse osmosis (RO), cooling water circulation, and industrial water reuse systems.
Available in single-vessel and multi-vessel configurations, the system can be designed for different flow rates, water quality conditions, operating pressures, and installation requirements.
Key Features
Graded Quartz Sand Media: Uses selected quartz sand and supporting gravel layers for depth filtration and suspended solids removal.
Uniform Water Distribution: Equipped with inlet distributors and bottom collection systems using slot nozzles or hub-lateral assemblies.
Pressure Vessel Construction: Available in carbon steel with internal epoxy coating, SS304, and SS316L construction.
Automatic Backwashing: Supports manual or automatic backwash control through multi-port valves or motorized butterfly valves.
Flexible System Configuration: Single-tank, parallel multi-tank, and skid-mounted configurations are available for different treatment capacities.
Accessible Maintenance: Manholes and service connections facilitate media replacement, internal inspection, and routine maintenance.
Technical Specifications
|
Parameter |
Specification |
|
Equipment Type |
Vertical pressure quartz sand filter |
|
Design Flow Rate |
5–300 m³/h per vessel |
|
Filter Surface Area |
0.5–15 m² per vessel |
|
Design Filtration Velocity |
5–15 m/h |
|
Operating Pressure |
0.2–0.6 MPa |
|
Operating Temperature |
5–50°C |
|
Vessel Material |
Q235B carbon steel, SS304, SS316L |
|
Internal Coating |
Anti-corrosion epoxy coating |
|
Quartz Sand Purity |
SiO₂ ≥99% |
|
Quartz Sand Effective Size |
0.45–1.2 mm |
|
Uniformity Coefficient |
≤1.7 |
|
Media Bed Depth |
1,000–1,200 mm |
|
Support Media |
Graded quartz gravel |
|
Backwash Method |
Water backwashing |
|
Backwash Control |
Manual or PLC automatic |
|
Control Components |
Siemens or Schneider PLC components |
|
Flange Standard |
ANSI, DIN, GB/T |
|
Power Supply |
220V/380V, 50Hz; 440V, 60Hz |
Applications
RO and UF Pretreatment: Removes suspended solids and reduces feedwater turbidity before membrane filtration systems.
Industrial Cooling Water: Filters suspended particles in side-stream circulation systems used in power plants, steel mills, and industrial cooling facilities.
Municipal Water Treatment: Processes surface water and groundwater before subsequent treatment and disinfection.
Wastewater Reuse: Reduces suspended solids in treated industrial wastewater before reuse or additional polishing processes.
Process Water Filtration: Provides particulate removal for manufacturing facilities requiring filtered water in production operations.
Working Principle
The industrial quartz sand filter operates through downward-flow depth filtration. Raw water enters the upper distribution system and passes evenly through the quartz sand bed. Suspended particles are captured through mechanical straining, sedimentation, and particle adhesion within the spaces between sand grains.
The filtered water passes through the supporting gravel layers and bottom collection system before leaving through the outlet.
As suspended solids accumulate in the media bed, filtration resistance increases and the differential pressure across the filter rises. When the preset pressure difference or backwash interval is reached, the system enters backwash mode.
During backwashing, water flows upward through the bottom distribution system, loosening the sand bed and removing accumulated impurities. The wastewater is discharged through the waste outlet. After the backwash and rinsing stages, the media settles and the filter returns to normal operation.
Quality Control & Manufacturing
Manufacturing inspection focuses on pressure vessel fabrication, internal components, coating quality, and equipment assembly.
Key quality control procedures include:
Material Inspection: Verification of vessel material grades and incoming material documentation.
Welding Inspection: Visual inspection and specified non-destructive testing of pressure vessel welds.
Surface Preparation: Internal steel surface preparation to Sa 2.5 before epoxy coating application.
Coating Inspection: Checking internal coating coverage and dry film thickness.
Hydrostatic Testing: Pressure testing according to the applicable vessel design code and approved inspection procedure.
Final Assembly: Inspection of distributors, collection nozzles, valves, piping connections, and control components.
FAQ
Q: What filtration performance can a quartz sand filter achieve?
A: Filtration performance depends on sand effective size, filtration velocity, media depth, and influent water quality. The target effluent turbidity should be established according to the downstream treatment requirements.
Q: How often should quartz sand media be replaced?
A: Quartz sand can typically operate for several years. Replacement frequency depends on media attrition, contamination, backwashing conditions, and actual operating performance.
Q: Can the filter operate continuously?
A: A single vessel requires interruption during backwashing. Parallel multi-vessel configurations allow other vessels to continue filtration while one unit undergoes backwashing.
Q: What information is required for equipment selection?
A: Provide the required flow rate, influent turbidity, suspended solids concentration, target effluent quality, operating pressure, water temperature, and available installation space.
Request a Quote
Contact us with your treatment capacity, raw water analysis, target filtration requirements, and installation conditions. Our engineering team can evaluate the filter surface area, quartz sand specifications, vessel material, and backwash configuration for your industrial water treatment project.
Hot Tags: quartz sand water filter, China quartz sand water filter manufacturers, suppliers, factory